Inspect the fluid for a milky appearance (indicating water contamination), or the presence of metal shavings (signaling internal component wear). If you notice either, flush the system immediately and contact your dealer for an inspection.
Quick Guide:
- Detach the hoses, lift the hydraulic unit from the headgear, and disconnect all wiring harnesses and the plow module.
- Unscrew the electric motor, hydraulic fittings, and valve coils from assembly.
- Carefully extract the cartridge valves from the block housing.
- Pull the quill assembly, remove the four reservoir screws, and extract the internal magnet, pump, and filter.
- Submerge all parts in a parts washer, using a pressurized hose to flush out every cavity within the valve block.
- Use a compressed air blow gun to remove all moisture, ensuring the block and all individual components are completely dry.
NOTE: If contamination was found in the main unit, it is crucial to also disassemble, clean, and flush all cylinders to ensure the entire system is free of debris.